Electrical connection
6.4 System integration
1PH1 main motors
78
Equipment Manual, 09/2021, A5E51077676A-AA
6.4.4.2
Fan terminal box
Connect the external fan via the fan terminal box. Implement operation of the fan via a
circuit breaker.
Terminal box connection
6.4.5
Connecting the terminal boxes
Note
•
The recommended sequence for cable connections is as follows: encoder cable first,
power cable next, and then the fan cable.
•
There are threaded holes available on both sides of the terminal box housing for you to
pass the cables through. You can select to connect the individual cables to the terminal
boxes from the threaded holes on the desired side.
•
No fan cable is provided at delivery. When connecting your own fan cable, make sure you
connect the fan terminals U, V, and W correspondingly to the line supply terminals L1, L2,
and L3 of the machine tool using appropriate cable connectors.