7.1
Safety notes
Safety measures for electromagnetic and permanent-magnetic fields
Note
Only qualified, suitably trained personnel who clearly understand the special hazards
involved may work with and on permanent-magnet rotor cores.
Note
Apply safety marking in accordance with the country-specific regulations at the assembly
stations for rotor cores.
•
Observe the relevant nationally applicable health and safety regulations.
•
Take measures, e.g. using shields, to reduce electromagnetic fields at their source.
•
Keep the motor components in their original packaging until installation.
•
Mark the storage location with the symbol for magnetic danger.
•
Place the unpacked rotor core in a safe place. Secure the rotor core with non-magnetic
devices.
•
Avoid contact of the rotor core with ferromagnetic bodies.
•
Preferably use tools made of non-magnetic materials. Ferromagnetic assembly tools must
have low mass. Work carefully!