Motor components and options
4.1 Motor components
SIMOTICS M-1FE2 built-in motors
Configuration Manual, 05/2021, A5E50494252B AB
63
Note
Install a backflush filter in the cooling circuit to prevent blockage and corrosion so that any
deposited material is flushed out.
4.1.3.3
Pressure loss
Volume flow and pressure drop in cooling circuit
Observe the nominal coolant flows specified in the following table to ensure that the motor is
cooled adequately.
Table 4- 7
Approximate pressure drop at the nominal coolant flow rate
Motor type
Values for the synchronous version
Flow rate Q
in l/min
Pressure drop dp
in MPa
1FE2182-8LN
☐☐
-
☐
CC1
9
0.3
1FE2182-8LH
☐☐
-
☐
CC1
9
0.3
1FE2183-8LN
☐☐
-
☐
CC1
10.5
0.4
1FE2183-8LH
☐☐
-
☐
CC1
10.5
0.4
1FE2184-8LN
☐☐
-
☐
CC1
12
0.5
1FE2184-8LK
☐☐
-
☐
CC1
12
0.5
1FE2184-8LH
☐☐
-
☐
CC1
12
0.5
1FE2185-8LN
☐☐
-
☐
CC1
13.5
0.6
1FE2185-8LL
☐☐
-
☐
CC1
13.5
0.6
1FE2185-8LH
☐☐
-
☐
CC1
13.5
0.6
1FE2186-8LN
☐☐
-
☐
CC1
15
0.8
1FE2186-8LM
☐☐
-
☐
CC1
15
0.8
1FE2186-8LH
☐☐
-
☐
CC1
15
0.8
1FE2187-8LN
☐☐
-
☐
CC1
16.5
1
1FE2187-8LH
☐☐
-
☐
CC1
16.5
1
Table 4- 8
Rated coolant volume flow
Motor type
Values for the asynchronous version
Volume flow Q in l/min
1FE209
☐
-8
☐☐☐☐
-
☐☐☐☐
8
1FE214
☐
-8
☐☐☐☐
-
☐☐☐☐
12
Pressure equalization
If various components are connected up in the cooling circuit, it may be necessary to provide
pressure equalization.
Reactor elements are installed at the coolant outlet of the motor or the relevant components.