Motor components and options
4.1 Motor components
SIMOTICS M-1FE2 built-in motors
Configuration Manual, 05/2021, A5E50494252B AB
51
Figure 4-1
Pt1000 characteristic
High short-term overload conditions require additional protective measures as a result of the
thermal coupling time of the temperature sensor.
Note
Temperature evaluation using only a Pt1000 does not guarantee full motor protection.
NOTICE
Destruction of the motor for a thermal critical load
A thermally critical load, e.g. high overload when the motor is stationary, can destroy the
motor.
•
Employ additional protective measures, e.g. an overcurrent relay.