Description
2.3 Technical features and system requirements
SIMOTICS M-1FE2 built-in motors
Configuration Manual, 05/2021, A5E50494252B AB
27
2.3.4
System requirements
System requirements for the closed-control
Ensure the following requirements:
•
Open-loop and closed-loop control modules
Synchronous motors
Asynchronous motors
From software release
From software release
SINAMICS S120
V4.8
5.2 SP3
SINUMERIK 828D sl
V4.8
4.94
SINUMERIK ONE
6.13
SINUMERIK 840D sl
4.94
Note
Operation with older software versions
If you operate the motors with older software versions, you must commission the motors
as if they were made by other manufacturers. This may involve limitations of the technical
performance.
Contact your Siemens Technical Support for more information.
•
Hollow-shaft measuring system
Parameterizing the converter
The rated data of the motors applies for a converter pulse frequency of 4 kHz.
Motors whose maximum speeds exceed the following speeds must be operated with a
converter frequency of 8 kHz and a current controller cycle of 62.5 µs.
•
1FE2...-8A...-.... : 12,000 rpm
•
1FE2...-8C...-.... : 12,000 rpm
Observe an appropriate Motor Module derating and the configuration specifications of the
S120. The rated motor current is the basis when selecting the Motor Module.