Connecting
8.2 Electrical connection
SIMOTICS M-1FE2 built-in motors
138
Configuration Manual, 05/2021, A5E50494252B AB
8.2.3.3
Conversion of the converter setting data
As standard, the 1FE218
☐
motor data always relates to the complete motor (both partial
windings) and is stored in the converter software. The values in the datasheets also refer to
the complete motor.
The values cannot be parameterized 1:1 for the master-slave operation. They must convert
the values to the individual subconverters.
The following example shows the conversion procedure.
Motor type: 1FE2184-8LH
☐☐
-
☐
CC1
V
motor
: 425 V