![Siemens SIMOTICS M-1FE2 Configuration Manual Download Page 127](http://html.mh-extra.com/html/siemens/simotics-m-1fe2/simotics-m-1fe2_configuration-manual_379035127.webp)
Connecting
8.2 Electrical connection
SIMOTICS M-1FE2 built-in motors
Configuration Manual, 05/2021, A5E50494252B AB
125
8.2.3
Version and operating modes
8.2.3.1
Connecting the synchronous version
Overview of connections with one power unit
The following chapter presents the circuit diagrams for possible connections to the SINAMICS
S120.
The circuit diagram contains information about wiring and connecting the motor winding.
The circuit diagram is provided in the motor packaging.
If you connect the associated motor cables of the two partial windings (1U1 and 2U1
→
U,
1V1 and 2V1
→
V, 1W1 and 2W1
→
W), operation with one power section is guaranteed.
Note
Connect a rotary encoder according to the project specifications.