Mechanical mounting
5.4 Mounting the stator with the spindle housing
1FE1 synchronous built-in motors
Hardware Installation Manual, 12/2016, 610.43000.40b
75
4.
Apply a suitable anti-corrosion agent for steel to the stator and spindle housing surfaces
that do not come into contact with the cooling fluid.
①
Stator core with cooling jacket
②
Spindle housing
③
O-ring seal
④
Surface coated with anti-corrosion agent
⑤
Drain hole
Figure 5-10 Applying anti-corrosion agent (the figure shows the fully mounted stator).
5.
To improve sliding, rub the O-ring seals with an appropriate grease or talcum.
2
The slots for the O-ring seals