Description
2.4 Technical features and environmental conditions
1FE1 synchronous built-in motors
26
Hardware Installation Manual, 12/2016, 610.43000.40b
2.4.2
Technical characteristics
Type of motor
Synchronous motor with permanent-magnet excited rotor (4, 6 or 8-pole)
Type of construction
Individual components (IM 5110 acc. to IEC 60034-7)
Stator, rotor
Degree of protection
IP00 (acc. to DIN IEC 60034, Part 5): Stator, rotor
Cooling
Water cooling with T
H2O
= 25° C acc. to EN 60034-1
Standard protection - temperature
monitoring
Two KTY 84 or Pt1000 PTC thermistors in the stator winding (1x reserve)
Full protection (optional)
In addition to the standard protection 1 x PTC thermistor triplet (3 sensors in series)
Can be evaluated, e.g. using a thermal motor protection unit:
Order No.: 3RN1013-1GW10
Universal protection (optional)
Full prot NTC PT3-51-F + NTC K227
Winding insulation
Temperature class 155 (F) acc. to EN 60034 permits an average winding tempera-
ture rise of 105 K. The power data is valid for a cooling water temperature of +5° -
25° C.
Balance quality of the rotor (acc. to
ISO 1940-1)
•
Rotor with sleeve:
Depending on the particular version, pre-balanced, balance quality G 2.5
reference speed 3600 rpm or non-balanced for complete balancing after mounting
and installation
•
Rotor without sleeve:
Not pre-balanced
Motor voltage
(terminal voltage)
regulated: Maximum 3 AC 430 V
rms
Non-regulated: Maximum 3 AC 460 V
rms
Supply voltage of the SINAMICS
S120 drive system
ALM 400 V → V
DC link
≦ 600 V
SLM 400 V → V
DC link
≦ 600 V
SLM 4
80 V → V
DC link
≦ 650 V
Note: For ALM 480 V infeed, a change must be made to "Smart Mode operation".
Type of connection
Free single cables U1, V1, W1 (cables freely brought out);
Length 0.5 m (preferred version) or 1.5 m
Torque ripple
1FE1 ... -6W
1FE1 ... -8W
1FE1 ... -4W
≦ 1% at 20 rpm and M
N
/2 referred to the rated torque
≦ 1% at 20 rpm and M
N
/2 referred to the rated torque
≦ 2% at 20 rpm and M
N
/2 referred to the rated torque
UL marking
With a few exceptions, motors are UL-1004 approved, see Chapter "Directives and
Note
Technical data is system data and is applicable only in conjunction with the specified system
components (1FE1 built-in motor, SINAMICS S120, VPM, IVP, etc.).