Operation
8.4 Stoppages
1FE1 synchronous built-in motors
Hardware Installation Manual, 12/2016, 610.43000.40b
135
8.4
Stoppages
Measures for longer non-operational periods
Note
Damage due to improper storage
The motor can be damaged if it is not stored properly.
•
If the motor is out of service for extended periods of time, implement suitable anti-
corrosion, preservation, and drying measures.
•
When recommissioning the motor after longer stoppages, perform the measures
recommended in Chapter "Commissioning".
●
Disconnect the motor from the cooling water system.
●
Remove any cooling water from the motor.
●
Blow out the cooling ducts with compressed air to dry them.
●
Observe the instructions for storage contained in Chapter "Transportation and storage
(Page 47)".
●
If the motor is not operational for extended periods of time, run it at regular intervals
(roughly once a month) or spin the rotor by hand.
●
Refer to the Chapter "Commissioning (Page 119)" before switching on for
recommissioning.