Connecting
6.2 Electrical connection
1FE1 synchronous built-in motors
Hardware Installation Manual, 12/2016, 610.43000.40b
109
1
Power cable
2
Signal line, trailable or only conditionally trailable
3
Signal connector, 17 pole, external thread, MLFB 6FX2003-1CF17
Optional assembly flange for retrofitting MLFB 6FX2003-7DX00
4
DRIVE-CLiQ cable 6FX
☐
002-
2DC10_☐☐☐, trailable or only conditionally trailable
5
SME120, encoder, motor side, connector kits 6FX2003-0SA12, 12-pin
6
Encoder
7
Temperature sensor (+1 reserve)
8
Ground connection
9
Voltage limiting (VPM, IVP), only if EMF > 820 V
Figure 6-3
Circuit diagram with SINAMICS (example)
Note
Connect a rotary encoder according to the project requirements.
6.2.9
Grounding
Ground the 1FE1 according to the project requirements.