Mechanical mounting
5.4 Mounting the stator with the spindle housing
1FE1 synchronous built-in motors
74
Hardware Installation Manual, 12/2016, 610.43000.40b
For joining by heating the spindle housing (shrink fit):
●
Hot-air oven with temperature monitoring
–
Oven volume appropriate for the stator type
–
Placement of the oven in the immediate vicinity of the workplace
●
Device for cooling the heated-up cooling jacket.
5.4.2
Mounting preparation
Procedure
1.
Check that the components are correct and complete.
2.
Check the insulation resistance before mounting stators that have been stored for a
longer period. See Chapter "Test the insulation resistance (Page 125)".
3.
Clean the surfaces to be joined
①
.
1
Joining surfaces for the stator to be coated with anti-corrosion agent.
2
Four slots for the O-ring seals for sealing the stator
3
Center slots for discharge in the drain holes
4
Cooling thread
Figure 5-9
Surfaces and slots for the stator with water cooling
All surfaces must be free from contamination, rust, sharp edges, shrink holes, damage
and machining marks, in particular:
–
The ring slots for the O-ring seals
–
The cooling thread on the cooling jacket (for the stator with cooling jacket variant)
–
The spindle housing
–
The cable duct in the spindle housing
–
The drain holes