Mechanical mounting
5.4 Mounting the stator with the spindle housing
1FE1 synchronous built-in motors
Hardware Installation Manual, 12/2016, 610.43000.40b
73
5.4
Mounting the stator with the spindle housing
5.4.1
Production equipment, assembly tools and other resources
Ensure the ambient conditions from Chapter Mounting instructions (Page 55).
Provide the following production equipment, assembly tools and other resources:
1
Appropriate axial stops (examples)
2
Lifting accessories (examples)
3
Eyebolts
4
Spacing sleeves
5
Plastic-covered support arm for horizontal mounting (example)
6
Internal tensioning spindle (example)
●
Occupational safety equipment:
–
Face protection shield
–
Protective gloves
–
Closed protective clothing for protection against high surface temperatures
●
Hoisting gear with suitable load suspension device for the stator core
●
Eyebolts or ring nuts and spacing sleeves
●
Axial stop for cooling jacket/stator core without cooling jacket
●
Internal tensioning spindle for the laminated stator core
●
Plastic-covered support arm (for horizontal mounting)
●
Anti-corrosion agent for steel surfaces
●
Grease or talcum as lubricants for Viton O-ring seals
For the leak test with liquid:
●
Water connection, maximum test pressure 0.7 MPa (7 bar).