Mechanical mounting
5.3 Mounting/dismantling the rotor
1FE1 synchronous built-in motors
Hardware Installation Manual, 12/2016, 610.43000.40b
71
Procedure
Table 5- 5
Dismantling the rotor core
Position before loosening
Position after loosening
①
Hydraulic hand pump connection
②
Connector nipple
③
Extension tube
④
Supporting fixture (prism)
⑤
Catchment tray
A Movement dimension = 55
mm, for the 1FE114□
-8 = 80 mm
A' Distance after loosening
1.
Unscrew both grub screws from the rotor core sleeve.
2.
Wrap the threaded shoulder on the extension tube and the second grub screw with Teflon
sealing tape.
3.
Screw the extension tube firmly into the sleeve of the rotor core.
4.
Place the rotor core with spindle shaft, slotted nut and the spacing sleeve on the prism.
5.
Attach the oil hand pump.
6.
Vent the hydraulic system.
7.
Screw the second grub screw with Teflon sealing tape tightly into the sleeve thread.
8.
Force the oil with the hand pump slowly until the pressure of approx. 50 MPa (500 bar) is
reached.
9.
Allow the oil to act for approximately 15 minutes.
→ The oil penetrates the fitting gaps and distributes itself.