Preparing for use
4.3 Transportation and storage
1FE1 synchronous built-in motors
Hardware Installation Manual, 12/2016, 610.43000.40b
49
Condensation
The following ambient conditions encourage the formation of condensation:
●
Significant fluctuations of the ambient temperature
●
Direct sunshine
●
High air humidity during storage
Avoid these ambient conditions.
Use a desiccant and a hygroscope in the packaging.
NOTICE
Risk of motor damage by voltage discharges resulting from condensation
If the stator winding is damp, its insulation resistance decreases. This can cause voltage
discharges that damage the windings.
•
Keep the drain holes free so that condensation can escape freely.
NOTICE
Risk of motor damage by corrosion resulting from condensation
Condensation that does not escape can cause corrosion and motor damage.
•
Keep the drain holes free so that condensation can escape freely.