Connecting
6.2 Electrical connection
1FE1 synchronous built-in motors
106
Hardware Installation Manual, 12/2016, 610.43000.40b
Motor type
L = 0.5 m
1)
L = 1.5 m
2)
Cable cross-section
per phase [mm
2
]
Cable outer
diameter [mm]
Cable cross-section
per phase [mm
2
]
Cable outer
diameter [mm]
1FE1092-
4WV□1
2.5
4.4
2.5
4.4
1FE1093-
4WH□1
10.0
7.9
16.0
9.0
1FE1093-
4WM□1
6.0
6.3
10.0
7.9
1FE1093-
4WN□1
6.0
6.3
10.0
7.9
1FE1094-
4WK□1
16.0
9.0
25.0
11.0
1FE1094-
4WL□1
10.0
7.9
16.0
9.0
1FE1094-
4WS□1
6.0
6.3
10.0
7.9
1FE1094-
4WU□1
4.0
5.5
6.0
6.3
1FE1095-
4WN□1
16.0
9.0
25.0
11.0
1FE1096-
4WN□1
16.0
9.0
25.0
11.0
1FE1103-
4WN□1
10.0
7.9
16.0
9.0
1FE1103-
4WQ□1
10.0
7.9
10.0
7.9
1FE1103-
4WT□1
6.0
6.3
10.0
7.9
1FE1104-
4WL□1
2 * 10
2 * 7.9
2 * 16
2 * 9
1FE1104-
4WN□1
16.0
9.0
25.0
11.0
1FE1105-
4WN□1
16.0
9.0
25.0
11.0
1FE1105-
4WQ□1
16.0
9.0
16.0
9.0
1FE1105-
4WS□1
10.0
7.9
16.0
9.0
1FE1106-
4WN□1
2 * 10
2 * 7.9
2 * 16
2 * 9
1FE1106-
4WR□1
25.0
11.0
2 * 16
2 * 9
1FE1106-
4WS□1
25.0
11.0
25.0
11.0
1FE1106-
4WY□1
6.0
6.3
10.0
7.9
1FE1124-
4WN□1
25.0
11.0
2 * 16
2 * 9
1FE1124-
4WQ□1
25.0
11.0
25.0
11.0
1FE1125-4W
N□1
2 * 16
2 * 9
2 * 16
2 * 9
1FE1125-
4WP□1
25.0
11.0
2 * 16
2 * 9
1FE1125-
4WQ□1
16.0
9.0
25.0
11.0
1FE1126-
4WN□1
2 * 16
2 * 9
2 * 16
2 * 9
1FE1126-
4WP□1
2 * 16
2 * 9
2 * 16
2 * 9
1FE1126-
4WQ□1
25.0
11.0
2 * 16
2 * 9
1) According to EN 46200, can be used only within the motor spindle.
Observe IEC / EN 60364-5-52 and IEC / EN 60204-1.
2) Notes on using cables is provided in VDE 0298, Part 3 and Part 4
3) Teflon cable