8.11.2
Electrical faults
Note
If you are operating the motor with a converter, the operating instructions of the converter must
also be observed if electrical faults occur.
Table 8-1
Electrical faults
↓ Motor fails to start
↓ Motor accelerates sluggishly
↓ Rumbling noise during startup
↓ Rumbling noise during operation
↓ High temperature rise during no-load operation
↓ High temperature rise with load
↓ High temperature rise of individual winding sections
Possible causes of faults
Remedial measures
X
X
X
X
Overload
Reduce the load.
X
Interrupted phase in the supply cable
Check the switches and cables.
X
X
X
X
Interrupted phase in the feeder cable af‐
ter switching on
Check the switches and cables.
X
Mains voltage too low, frequency too high Check the power supply conditions.
X
Mains voltage too high, frequency too low Check the power supply conditions.
X
X
X
X
X Stator winding incorrectly connected
Check the winding connection in the terminal box.
X
X
X
X Winding short circuit or phase short cir‐
cuit in stator winding
Determine the winding resistances and insulation
resistances. Carry out repair work after consulta‐
tion with the manufacturer.
X
Incorrect direction of rotation
Check the connection.
8.11.3
Mechanical faults
Table 8-2
Mechanical faults
↓ Grinding noise
↓ Radial vibrations
↓ Axial vibrations
Possible causes of faults
Remedial measures
X
Rotating parts grind
Establish the cause and realign the parts.
X
Stator or coupling not balanced.
Disconnect the stator or coupling and rebalance.
If the machine has two shaft ends, and a transmission element is
only fitted to one end, secure the fitted key at the other end to prevent
it from being thrown out. If the rotor has balance type "H" (standard
type), the fitted key must be cut back to roughly half of its length.
Operation
8.11 Faults
SIMOTICS HV M 1RN76308PR900CG0-Z
Operating Instructions 07/2018
83
Summary of Contents for SIMOTICS HV M
Page 2: ...03 07 2018 13 28 V3 00 ...
Page 22: ...Description SIMOTICS HV M 1RN76308PR900CG0 Z 22 Operating Instructions 07 2018 ...
Page 86: ...Operation 8 11 Faults SIMOTICS HV M 1RN76308PR900CG0 Z 86 Operating Instructions 07 2018 ...
Page 122: ...Service and Support SIMOTICS HV M 1RN76308PR900CG0 Z 122 Operating Instructions 07 2018 ...
Page 128: ...Quality documents SIMOTICS HV M 1RN76308PR900CG0 Z 128 Operating Instructions 07 2018 ...
Page 130: ...Additional documents SIMOTICS HV M 1RN76308PR900CG0 Z 130 Operating Instructions 07 2018 ...
Page 135: ......