4.16.2
Insulated bearings when operating the converter
Operation with a medium-voltage converter with insulated coupling and insulated bearings
If the machine is fed from a 3-level voltage-source DC link converter without a sine-wave filter,
then shaft grounding is fitted at the NDE. The shaft grounding can be implemented as a
grounding device or incorporated in the tachometer. The DE and NDE bearings are insulated.
● Comply with the plates on the machine relating to bearing insulation and possible bridging
options.
● Use an insulated coupling to connect the motor to the driven machine. Otherwise, the
bearing insulation at the DE is bypassed. The consequence of that would be a circulating
current through the motor shaft and the surrounding grounding system.
WARNING
Defective shaft grounding
If the shaft grounding does not function correctly, the shaft can be at a high voltage level that
does not decay quickly enough when the machine comes to a standstill. This can lead to
death or serious injury as a result of electric shock, or bearing damage caused by current
flowing through the bearing.
● Regularly check the shaft grounding and maintain it at the maintenance intervals.
● Observe the operating instructions for the shaft grounding.
①
Driving machine
④
Insulated bearings
②
Motor
⑤
Insulated tachometer fitting
③
Insulated coupling
⑥
Shaft grounding
Figure 4-2
Schematic representation of a single drive
Preparations for use
4.16 Converter operation
SIMOTICS HV M 1RN76308PR900CG0-Z
36
Operating Instructions 07/2018
Summary of Contents for SIMOTICS HV M
Page 2: ...03 07 2018 13 28 V3 00 ...
Page 22: ...Description SIMOTICS HV M 1RN76308PR900CG0 Z 22 Operating Instructions 07 2018 ...
Page 86: ...Operation 8 11 Faults SIMOTICS HV M 1RN76308PR900CG0 Z 86 Operating Instructions 07 2018 ...
Page 122: ...Service and Support SIMOTICS HV M 1RN76308PR900CG0 Z 122 Operating Instructions 07 2018 ...
Page 128: ...Quality documents SIMOTICS HV M 1RN76308PR900CG0 Z 128 Operating Instructions 07 2018 ...
Page 130: ...Additional documents SIMOTICS HV M 1RN76308PR900CG0 Z 130 Operating Instructions 07 2018 ...
Page 135: ......