9.3.5
Seal the motor
Extreme caution and attention to cleanliness are vital to installation.
● Clean all bare joints between parts such as housings, bearing shields and bearing bushes
etc., and remove old sealant material.
● Smear bare joints between parts with non-hardening, permanently flexible sealant, such
as "Hylomar M". Follow the manufacturer's application and safety instructions when doing
this.
● Check all sealing elements, such as those on the terminal boxes, for elasticity, aging or
damage, and renew them if they are no longer effective.