Drive
The motor speed is controlled using a converter. It has been optimized for operation with
SINAMICS low-voltage converters.
Other converters must comply with certain requirements: You can find more information in the
catalog or in the engineering documentation.
NOTICE
Destruction of the machine when operated directly from the line supply
The machine will be destroyed if it is directly connected to the line supply. Only operate the
machine using a converter.
Cooling
The cooling system is designed as a closed, internal cooling circuit. The heat lost from the
machine is dissipated to the ambient air via the machine's surface. A shaft-mounted fan moves
the cooling air in the primary circuit. Movement of the cooling air in the external circuit is
generated by a separately-driven fan unit.
Degree of protection
The machine is available with degree of protection IP55.
Rolling-contact bearings
The machines are equipped with different types of rolling-contact bearings depending on the
version and the operating conditions described in the order. The different types are listed on the
lubricant plate of the machine. In converter operation an insulated bearing is usually installed
on the non-drive end. The following rolling-contact bearing variants are available:
Table 3-4
Rolling-contact bearing variants
Version
Rolling-contact bearing
Horizontal type of construction,
coupling output
● Drive end: Deep-groove ball bearing as a fixed bearing
● Non-drive end: Deep-groove ball bearing as a floating bearing
with axial compression springs
Horizontal type of construction,
for increased transverse forces
e.g. in the case of belt coupling
● Drive end: Cylindrical-roller bearing as a floating bearing
● Non-drive end: Deep-groove ball bearing as a fixed bearing
Description
SIMOTICS FD 1MQ1
26
Operating Instructions 01/2019
Summary of Contents for SIMOTICS FD 1MQ1
Page 2: ...28 01 2019 14 14 V11 01 ...
Page 144: ...Maintenance 9 2 Corrective Maintenance SIMOTICS FD 1MQ1 144 Operating Instructions 01 2019 ...
Page 170: ...Disposal 11 5 Disposal of components SIMOTICS FD 1MQ1 170 Operating Instructions 01 2019 ...
Page 172: ...Service and Support SIMOTICS FD 1MQ1 172 Operating Instructions 01 2019 ...
Page 176: ...Quality documents SIMOTICS FD 1MQ1 176 Operating Instructions 01 2019 ...
Page 181: ......