![Siemens SIMOTICS FD 1MQ1 Operating And Installation Instructions Download Page 103](http://html.mh-extra.com/html/siemens/simotics-fd-1mq1/simotics-fd-1mq1_operating-and-installation-instructions_379025103.webp)
5. Enter the appropriate motor data in the "Motor data" table in the "Value" column.
– You can find the values for parameters p304...p311 on the motor rating plate.
– The value for parameter p335 (motor cooling method) is encrypted from the motor order
number:
Motor order number
Cooling method
Parameter p335
1LL1
IC01
0
1LP1
IC06
1
1LM1/1MM1
IC411
4
1LQ1/1MQ1
IC416
5
1LH1/1MH1
IC71W
6
1LN1/1MN1
IC86W
6
Figure 7-2
Entering the motor data
6. Click "Continue" to confirm your entries.
Start-up
7.11 Setting the motor parameters at the converter
SIMOTICS FD 1MQ1
Operating Instructions 01/2019
103
Summary of Contents for SIMOTICS FD 1MQ1
Page 2: ...28 01 2019 14 14 V11 01 ...
Page 144: ...Maintenance 9 2 Corrective Maintenance SIMOTICS FD 1MQ1 144 Operating Instructions 01 2019 ...
Page 170: ...Disposal 11 5 Disposal of components SIMOTICS FD 1MQ1 170 Operating Instructions 01 2019 ...
Page 172: ...Service and Support SIMOTICS FD 1MQ1 172 Operating Instructions 01 2019 ...
Page 176: ...Quality documents SIMOTICS FD 1MQ1 176 Operating Instructions 01 2019 ...
Page 181: ......