AA87
2
Ex
nA
IIB
T3
Gc
X
①
⑪
②
⑫
⑥
⑦
⑧
⑨
⑩
⑬
①
CE- or EAC marking
②
Code for prevention of explosions
③
Equipment group: II not for mining, but other hazardous zones
④
Device category: 3 for infrequent, short-term danger
⑤
Atmosphere: G for gas
⑥
Explosion protection: International
⑦
"nA" or "ec" type of protection
⑧
Explosion group: IIB for ethylene
⑨
Temperature Class: T3 for maximum surface temperature 200 °C
⑩
Device protection level: Gc for an extended level of protection in hazardous zones with
explosive gas mixtures
⑪
Identification number or name of nominated testing agency
⑫
Zone 2
⑬
"X" special conditions
Rating plate
The rating plate shows the identification data and the most important technical data. The data
on the rating plate and the contractual agreements define the limits of proper usage.
Description
3.1 Comparison of IEC and GOST standards
SIMOTICS FD 1MH1
26
Operating Instructions 08/2017
Summary of Contents for SIMOTICS FD 1LL1
Page 2: ...18 08 2017 17 24 V10 00 ...
Page 176: ...Disposal 11 4 Disposal of components SIMOTICS FD 1MH1 176 Operating Instructions 08 2017 ...
Page 178: ...Service and Support SIMOTICS FD 1MH1 178 Operating Instructions 08 2017 ...
Page 182: ...Quality documents SIMOTICS FD 1MH1 182 Operating Instructions 08 2017 ...
Page 187: ......