5. Enter the appropriate motor data in the "Motor data" table in the "Value" column.
– You can find the values for parameters p304...p311 on the motor rating plate.
– The value for parameter p335 (motor cooling method) is encrypted from the motor order
number:
Motor order number
Cooling method
Parameter p335
1LL1
IC01
0
1LP1
IC06
1
1LM1/1MM1
IC411
4
1LQ1/1MQ1
IC416
5
1LH1/1MH1
IC71W
6
1LN1/1MN1
IC86W
6
Figure 7-2
Entering the motor data
6. Click "Continue" to confirm your entries.
Start-up
7.10 Setting the motor parameters at the converter
SIMOTICS FD 1MH1
Operating Instructions 08/2017
115
Summary of Contents for SIMOTICS FD 1LL1
Page 2: ...18 08 2017 17 24 V10 00 ...
Page 176: ...Disposal 11 4 Disposal of components SIMOTICS FD 1MH1 176 Operating Instructions 08 2017 ...
Page 178: ...Service and Support SIMOTICS FD 1MH1 178 Operating Instructions 08 2017 ...
Page 182: ...Quality documents SIMOTICS FD 1MH1 182 Operating Instructions 08 2017 ...
Page 187: ......