Assembly
5.4 Installation
Smoke extraction motors
Operating Instructions, 03/2016, 5 610 80000 40 018
43
5.4.5.1
Mounting and withdrawing output transmission elements
Withdrawing output transmission elements
Mounting output transmission elements
●
When mounting output transmission elements (coupling, gear wheel, belt pulley etc. ) use
the thread at the shaft end.
If possible, heat up the output transmission elements as required.
●
Use a suitable device when withdrawing output elements.
●
When mounting or withdrawing, do not apply any blows, for example with a hammer or
similar tool, to the parts to be mounted or withdrawn.
●
Only transfer radial or axial forces specified in the catalog to the motor bearings via the
shaft extension.