SIMOCODE pro PCS 7 Library V9.0
Programming and Operating Manual, 06/2017, A5E40899442002A/RS-AA/001
283
Technical Data
B
Table B- 1
Memory space requirements and called blocks per block type for SIMOCODE pro PCS 7 Library V9.0
Block
1
No.
2
Length of
block in the
load
memory, in
bytes
3
Length of
block in the
work memory,
in bytes
3
Length of
instance data
in the load
memory, in
bytes
4
Length of
instance data
in the work
memory, in
bytes
4
Temporary
memory, in
bytes
5
Blocks
called
6
MMDiag
FB1300 8736
7368
1602
468
198
FC369,
SFC51,
SFC6,
SFC64
MMOprtn
FB1301 21680
18286
3834
1424
454
FC369,
SFC13,
SFC6,
SFC64,
SFC20
MMMeas
FB1302 18826
16362
2494
1050
166
FC369,
SFC6,
SFC64,
SFC20
MMStat
FB1303 6302
5090
1918
846
86
FC369,
SFC6,
SFC20
MMLog
FB1304 19362
17192
4036
2400
216
FC369,
SFC6,
SFC20
MMRevDhl FB1305 26728
24234
2734
920
110
FC369,
SFC6,
SFC20
1
The symbolic designator in the symbol table of the library for the respective function block (FB). It must be unique within
the project.
2
Consists of the type of block (FB) and the number.
3
Memory requirement of program code, once per block type
4
Memory requirement for an instance data block.
5
The memory required for the local data when the block is called in an execution level. This is limited according to the
specific CPU. If this amount is exceeded, you must check the setting in the CPU configuration and redistribute it among
the organization blocks based on the actual requirement.
6
The relevant driver block uses these blocks. They are now located in the user program. They are stored in the same
library.