Parameters
Range
Note
Trip level
0.00 - 40.00 A
-
Warning level
0.00 - 40.00 A
-
0/4-20 mA monitoring
→
0/4-20 mA limits
Possible only if analog module 1 and/or 2 is
configured
Analog module 1 - trip level
0/4-20 mA > (upper limit)
0 - 255
Represented in 0/4 - 20 mA similar to
"Measured values" menu
Analog module 1 - warning level
0/4-20 mA > (upper limit)
0 - 255
Represented in 0/4 - 20 mA similar to
"Measured values" menu
Analog module 1 - trip level
0/4-20 mA < (lower limit)
0 - 255
Represented in 0/4 - 20 mA similar to
"Measured values" menu
Analog module 1 - warning level
0/4-20 mA < (lower limit)
0 - 255
Represented in 0/4 - 20 mA similar to
"Measured values" menu
Analog module 2 - trip level
0/4-20 mA > (upper limit)
0 - 255
Represented in 0/4 - 20 mA similar to
"Measured values" menu
Analog module 2 - warning level
0/4-20 mA > (upper limit)
0 - 255
Represented in 0/4 - 20 mA similar to
"Measured values" menu
Analog module 2 - trip level
0/4-20 mA < (lower limit)
0 - 255
Represented in 0/4 - 20 mA similar to
"Measured values" menu
Analog module 2 - warning level
0/4-20 mA < (lower limit)
0 - 255
Represented in 0/4 - 20 mA similar to
"Measured values" menu
Temperature monitoring
→
temperature limits
Possible only if temperature module 1 and/or 2 is
configured
Temperature module 1 -
trip level > (upper limit)
0 - 65,535 K
Represented in °C/F similar to "Measured values"
menu
Temperature module 1 -
warning level > (upper limit)
0 - 65,535 K
Represented in °C/F similar to "Measured values"
menu
Temperature module 2 -
trip level > (upper limit)
0 - 65,535 K
Represented in °C/F similar to "Measured values"
menu
Temperature module 2 -
warning level > (upper limit)
0 - 65,535 K
Represented in °C/F similar to "Measured values"
menu
Limit monitor - limit monitor limit
0 - 65535
-
Limit 1
0 - 65535
-
Limit 2
0 - 65535
-
Limit 3
0 - 65535
-
Limit 4
0 - 65535
-
Limit 5
0 - 65535
-
Limit 6
0 - 65535
-
Note
Password protection
It is only possible to change these parameters if password protection is not active. Only then
can you choose the parameter to be modified with the "OK" button.
Summary of Contents for SIMOCODE pro C
Page 40: ...Areas of application SIMOCODE pro 40 System Manual 05 2019 A5E40507475002A RS AD 004 ...
Page 46: ...Features SIMOCODE pro 46 System Manual 05 2019 A5E40507475002A RS AD 004 ...
Page 178: ...Accessories SIMOCODE pro 178 System Manual 05 2019 A5E40507475002A RS AD 004 ...
Page 398: ...Glossary SIMOCODE pro 398 System Manual 05 2019 A5E40507475002A RS AD 004 ...