![Siemens SIMATIC VS130 Series Manual Download Page 39](http://html.mh-extra.com/html/siemens/simatic-vs130-series/simatic-vs130-series_manual_374431039.webp)
Operator Functions
Vision Sensor VS 130
A5E00199459-01
5-9
5.3.4 "Settings"
Menu
With the "Settings" menu, you set the parameters required for operation. It contains
the following submenus:
•
Ports: To specify or assign parameters to the ports
•
Read: to set the parameters for image evaluation
•
Match: To compare the read codes with a string
•
Result: To output the read codes
•
Reset All: To set all the parameters of the "Settings" menu to the default
Step
Display
Activity
1
RUN
Adjust
> Settings
↕
OK
You are at the "STOP" menu level. Select "Settings" with the arrow
buttons
▼
and
▲
and press "OK".
Note
The current setting for all parameters that can only be activated or deactivated is
indicated by "
√
".
"Ports" Submenu
In the "Ports" submenu, you specify the ports and assign parameters for them.
Menu Entry or Parameter
Possible
Values
Default
Meaning
Address
001 to 125
007
Address on PROFIBUS DP
DP
Timeout
100 to 2000
500
Handshake monitoring time in ms
Bit rate
9600, 14400,
19200, 28800,
38400, 57600,
115200
115200
Bit rate in bits / s
Stop bits
1, 2
2
Number of stop bits
Parity
Even, Odd,
None
Even
Parity
RS-232
Bits
7, 8
8
Number of data bits
Result
String
DP, RS-232
RS-232
Port via which the processing unit
provides the read code