3-16
SIMATIC TD 200 Operator Interface
C79000-G7076-C272-01
3.8
Using the TD 200 Setup Menu Option
The TD 200 Setup menu allows you to set the network address of the TD 200 and
the S7-200 CPU, the address of the parameter block (stored in V memory of the
CPU), the baud rate, and other communication parameters. The display contrast
adjustment is also available in the TD 200 Setup menu.
The network addresses allow the TD 200 to be connected to a network with
multiple master and slave devices. Entering the address where the TD 200 looks
for its parameter block allows you to have several TD 200 devices connected to a
single CPU.
Note
Pressing ESC while not editing a value returns you to the Display Message mode.
If any of the Setup menu items have been changed, the TD 200 stores the new
values permanently and reinitializes the communications to the CPU.
Setting the Network Address of the TD 200
The Setup Menu allows you to enter the network address for the TD 200. (The
default address for the TD 200 is 1.) Use the following procedure to change the
network address for the TD 200:
Key
Action
Display
1.
ESC
The TD 200 enters the Menu mode.
VIEW MESSAGES
MENU MODE:
2.
The TD 200 scrolls down the menu
options five times.
TD 200 ADDRESS
1
SETUP MENU:
3.
ENTER
Press
ENTER
to move the cursor to the
address field. Use the up or down
arrow keys to display the correct
address.
SETUP MENU:
TD 200 ADDRESS
1
4.
ENTER
Press
ENTER
to store the new address
for the TD 200.
SETUP MENU:
TD 200 ADDRESS
2
Operating the TD 200
Summary of Contents for SIMATIC TD 200
Page 22: ...1 12 SIMATIC TD 200 Operator Interface C79000 G7076 C272 01 Product Overview and Installation ...
Page 84: ...A 12 SIMATIC TD 200 Operator Interface C79000 G7076 C272 01 Specifications and Reference ...
Page 94: ...B 10 SIMATIC TD 200 Operator Interface C79000 G7076 C272 01 Multiple CPU Configurations ...
Page 126: ...E 6 SIMATIC TD 200 Operator Interface C79000 G7076 C272 01 Modifying a TD 200 Configuration ...