Data error
When do data errors occur?
If new parameters are transferred to the module, the FM 450-1 checks these parameters. If
errors occur during this check, the module reports these data errors.
Wrong parameters are not accepted by the module.
Where are data errors indicated?
The FC CNT_CTRL enters the data errors in DB1 with the error numbers. You can access
this data word via the variable name "DA_ERR_W" in the user program The following table
shows the numbers of the data errors and the significance of these errors.
Table 11- 3 Data error numbers and their significance
No.
Meaning
0
No fault
201
Value too great for receiver selection
202
Value too great for the diagnostics of the pair of signals
203
Value too great for the evaluation of the signals
204
Value too great for the input filter of the 24V count signals
205
Value too great for the input filters of the digital inputs
206
Reversing the direction not permitted
207
Value too great for the behavior of digital output 1Q0 (2Q0)
208
Value too great for the behavior of digital output 1Q1 (2Q1)
209
Pulse duration wrong or too long
211
Wrong mode selected
212
No gate or both gates specified
215
When assigning the process interrupt "Reaching the comparison value in the up and/or down
count direction" parameters a different count direction was specified than the parameter
assignment for the behavior of the outputs "Output active for on pulse duration in up and/or
down direction". The directions must match.
216
Gate control interrupts are only possible for modes with gate control
217
No interrupt on reaching the comparison values is permitted for behavior of the digital outputs
"active between comparison value and overflow" or "active between comparison value and
underflow".
How are data errors acknowledged?
Correct the values for the parameters to comply with the specifications. Transfer the
corrected set of parameters to the FM 450-1 again. This again checks the parameters and
deletes the data error in DB 1.
Summary of Contents for simatic s7-400 FM 450-1
Page 8: ...Table of contents Counter module FM 450 1 8 Manual 02 2014 A5E03648739 02 ...
Page 120: ...Spare parts Counter module FM 450 1 120 Manual 02 2014 A5E03648739 02 ...
Page 122: ...References Counter module FM 450 1 122 Manual 02 2014 A5E03648739 02 ...
Page 126: ...Glossary Counter module FM 450 1 126 Manual 02 2014 A5E03648739 02 ...
Page 130: ...Index Counter module FM 450 1 130 Manual 02 2014 A5E03648739 02 ...