Special memory (SM) and system symbol names
D.14 SMB36-SMB45 (HSC0), SMB46-SMB55 (HSC1), SMB56-SM65 (HSC2), SMB136-SMB145 (HSC3),
SMB146-SMB155 (HSC4), SMB156-SMB165 (HSC5): high-speed counters
S7-200 SMART
810
System Manual, V2.3, 07/2017, A5E03822230-AF
D.14
SMB36-SMB45 (HSC0), SMB46-SMB55 (HSC1), SMB56-SM65
(HSC2), SMB136-SMB145 (HSC3), SMB146-SMB155 (HSC4),
SMB156-SMB165 (HSC5): high-speed counters
These bytes provide configuration and operation information for the high-speed counters:
●
HSC0
●
HSC1
●
HSC2
●
HSC3
●
HSC4
●
HSC5
Table D- 9 HSC0 configuration and operation
S7-200 SMART
symbol name
SM address
Description
HSC0_Status
SMB36
HSC0 counter status
Note: Counter status bits are valid only while the CPU is executing an inter-
rupt routine that a high-speed counter event triggered.
SM36.0–SM36.4
Reserved
HSC0_Status_5
SM36.5
HSC0 current counting direction status bit: TRUE: Counting up
HSC0_Status_6
SM36.6
HSC0 current value equals preset value status bit: TRUE: Equal
HSC0_Status_7
SM36.7
HSC0 current value is greater than preset value status bit: TRUE: Greater
than
HSC0_Ctrl
SMB37
HSC0 counter control
HSC0_Reset_Level
SM37.0
HSC0 active level control bit for Reset: FALSE: Reset is active high, TRUE:
Reset is active low
SM37.1
Reserved
HSC0_Rate
SM37.2
HSC0 counting rate selection for Quadrature counters: FALSE: 4x counting
rate; TRUE: 1x counting rate
HSC0_Dir
SM37.3
HSC0 direction control bit: TRUE: Count up
HSC0_Dir_Update
SM37.4
HSC0 update direction: TRUE: update direction
HSC0_PV_Update
SM37.5
HSC0 update preset value: TRUE: Write new preset value to HSC0 preset
HSC0_CV_Update
SM37.6
HSC0 update current value: TRUE: Write new current value to HSC0 cur-
rent
HSC0_Enable
SM37.7
HSC0 enable bit: TRUE: enable