IPC COM Port

When connecting IPC with an External Device, the COM port used depends on the series and SIO type. Please 

refer to the IPC manual for details.

Usable port

DIP switch setting: RS-232C

Series

Usable Port

RS-232C

RS-422/485(4 wire)

RS-422/485(2 wire)

PS-2000B

COM1

*1

, COM2, 

COM3

*1

, COM4

*1

The RI/5V can be switched. Use the IPC’s switch to change if necessary.

-

-

PS-3450A, PS-3451A,
PS3000-BA, PS3001-BD

COM1, COM2

*1*2

COM2

*1*2

COM2

*1*2

PS-3650A, PS-3651A

COM1

*1

-

-

PS-3700A (Pentium®4-M)
PS-3710A

COM1

*1

, COM2

*1

COM3

*2

, COM4

*2

Set up the SIO type with the DIP switch. Please set up as follows according to SIO type to be used.

COM3

*2

COM3

*2

PS-3711A

COM1

*1

, COM2

*2

COM2

*2

COM2

*2

PL-3000B, PL-3600T,
PL-3600K, PL-3700T,
PL-3700K, PL-3900T

COM1

*1*2

, COM2

*1

COM3, COM4

COM1

*1*2

COM1

*1*2

DIP switch

Setting

Description

1

OFF

*1

*1

When using PS-3450A, PS-3451A, PS3000-BA and PS3001-BD, turn ON the set value.

Reserved (always OFF)

2

OFF

SIO type: RS-232C

3

OFF

4

OFF

Output mode of SD (TXD) data: Always output

5

OFF

Terminal resistance (220

Ω

)  insertion to SD (TXD): None

6

OFF

Terminal resistance (220

Ω

)  insertion to RD (RXD): None

7

OFF

Short-circuit of SDA (TXA) and RDA (RXA): Not available

8

OFF

Short-circuit of SDB (TXB) and RDB (RXB): Not available

9

OFF

RS (RTS) Auto control mode: Disabled

10

OFF

Summary of Contents for SIMATIC S5 CPU Direct Driver

Page 1: ... CPU Direct Driver 1 System Configuration 3 2 Selection of External Device 6 3 Example of Communication Setting 7 4 Setup Items 8 5 Cable Diagram 13 6 Supported Device 14 7 Device Code and Address Code 15 8 Error Messages 16 ...

Page 2: ... Device Select a model series of the External Device to be connected and connection method Selection of External Device page 6 3 Example of Communication Settings This section shows setting examples for communicating between the Display and the External Device Example of Communication Setting page 7 4 Setup Items This section describes communication setup items on the Display Set communication set...

Page 3: ...e connected is shown Connection Configuration 1 1 Connection Series Name CPU Link I F SIO Type Setting Example Cable Diagram Series 90U 115U CPU 90U CPU 95U CPU 100 CPU 102 CPU 103 CPU 941 CPU 942 CPU 943 CPU 944 PG port on CPU RS232C Setting Example 1 page 7 Cable Diagram 1 page 13 Series 135U 155U CPU 922 CPU 928 CPU 928B PG port on CPU RS232C Display External Device CA6 CBLTTY 5M 01 ...

Page 4: ...OM1 1 COM2 1 COM3 2 COM4 2 Set up the SIO type with the DIP switch Please set up as follows according to SIO type to be used COM3 2 COM3 2 PS 3711A COM1 1 COM2 2 COM2 2 COM2 2 PL 3000B PL 3600T PL 3600K PL 3700T PL 3700K PL 3900T COM1 1 2 COM2 1 COM3 COM4 COM1 1 2 COM1 1 2 DIP switch Setting Description 1 OFF 1 1 When using PS 3450A PS 3451A PS3000 BA and PS3001 BD turn ON the set value Reserved a...

Page 5: ...ion to RD RXD None 7 OFF Short circuit of SDA TXA and RDA RXA Not available 8 OFF Short circuit of SDB TXB and RDB RXB Not available 9 OFF RS RTS Auto control mode Disabled 10 OFF DIP switch Setting Description 1 OFF Reserved always OFF 2 ON SIO type RS 422 485 3 ON 4 OFF Output mode of SD TXD data Always output 5 OFF Terminal resistance 220Ω insertion to SD TXD None 6 OFF Terminal resistance 220Ω...

Page 6: ...age 3 Use System Area Check this option when you synchronize the system data area of the Display and the device memory of the External Device When synchronized you can use the ladder program of the External Device to switch the display or display the window on the Display Cf GP Pro EX Reference Manual Appendix 1 4 LS Area Direct Access Method This can be also set with GP Pro EX or in off line mode...

Page 7: ...hown 3 1 Setting Example 1 Settings of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings Settings of External Device The communication setting of the External Device is ...

Page 8: ...a Length Displays data length Parity Displays how to check parity Stop Bit Displays stop bit length Flow Control Displays the communication control method to prevent overflow of transmission and reception data Timeout Use an integer from 1 to 127 to enter the time s for which the Display waits for the response from the External Device Retry In case of no response from the External Device use an in...

Page 9: ...LC Connection Manual 9 Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings Setup Items Setup Description Series Select a model of the External Device ...

Page 10: ...ems Setup Description SIO Type Select the SIO type to communicate with the External Device To make the communication settings correctly confirm the serial interface specifications of Display unit for SIO Type We cannot guarantee the operation if a communication type that the serial interface does not support is specified For details concerning the serial interface specifications refer to the manua...

Page 11: ... from the External Device use an integer from 0 to 255 to enter how many times the Display retransmits the command Wait To Send Use an integer from 0 to 255 to enter standby time ms for the Display from receiving packets to transmitting next commands Setup Items Setup Description Device PLC Name Select the External Device to set Device name is a title of the External Device set with GP Pro EX Init...

Page 12: ...xternal Device you want to set from the displayed list and touch Option Setup Items Setup Description RI VCC You can switch RI VCC of the 9th pin if you select RS232C for SIO type It is necessary to change RI 5V by changeover switch of IPC when connect with IPC Please refer to the manual of the IPC for more detail GP 4100 series do not have the Option setting in the off line mode ...

Page 13: ... short circuit loop Connect the isolation unit when communication is not stabilized under the influence of a noise etc Cable Diagram 1 1A 1B Display Connection Port Cable Remarks GP3000 COM1 ST COM1 IPC 1 PC AT 1 Only the COM port which can communicate by RS 232C can be used IPC COM Port page 4 1A SIEMENS TTY converter cable by Pro face CA6 CBLTTY 5M 01 5m GP 4105 COM1 1B User created cable SIEMEN...

Page 14: ...rence Manual for system data area Cf GP Pro EX Reference Manual Appendix 1 4 LS Area Direct Access Method Please refer to the precautions on manual notation for icons in the table Manual Symbols and Terminology Device Bit Address Word Address 32 bit Remarks Input Relay I000 0 I127 7 IW000 IW126 Output Relay Q000 0 Q127 7 QW000 QW126 Internal Relay F000 0 F255 7 FW000 FW254 Timer T000 T255 Counter ...

Page 15: ...ord address divided by 2 Output Q 0081 Value of word address divided by 2 Internal Relay F 0082 Value of word address divided by 2 Timer T 0060 Word Address Counter C 0061 Word Address Device Device Name Device Code HEX Address Code Data Block DB 0000 Value of Data Block No x 0x10000 word address Extended Data Block X 0001 Value of Extended Data Block No x 0x10000 word address Input I 0080 Value o...

Page 16: ...xternal Device set with GP Pro EX Initial value PLC1 Error Message Displays messages related to the error which occurs Error Occurrence Area Displays IP address or device address of the External Device where error occurs or error codes received from the External Device IP address is displayed such as IP address Decimal MAC address Hex Device address is displayed such as Address Device address Rece...

Reviews: