9.1.7.4
Grease service life and fill quantities
Standard roller bearings
Size
Grease stability time for permanent lubrication or relubrication
interval
for a regreasing system in operating hours at rated speed
Grease filling quantity for permanent
lubrication or grease quantity for
relubrication in g per bearing
Horizontal type of construction
(B)
Vertical type of construction (V)
Permanent
lubrication
Relubrication
3000
rpm
1500
rpm
≤1000
rpm
3000
rpm
1500
rpm
≤1000
rpm
3000
rpm
≤1500
rpm
3000
rpm
≤1500
rpm
71
33000
40000
40000
33000
40000
40000
9
9
-
-
80
9
9
-
-
90
11
11
-
-
100
25
25
-
-
112
25
25
-
-
132
24000
16000
26000
50
50
-
-
160
80
80
-
-
180
100
100
-
-
200
130
130
-
-
225
190
190
-
-
250
190
190
-
-
280
190
260
-
-
315
4000
8000
11000
2800
5600
8000
-
-
35
25
355
-
-
35
50
The specified grease service lives or relubrication intervals are valid for a maximum ambient
temperature of 40° C. For every 10° C increase in temperature, reduce the lubrication interval
specified in the table by a factor of 0.7 (max. 20° C = factor 0.5). With an ambient temperature
<= 25° C, twice the grease stability time can be expected; but a maximum of 40000 hours.
Times for operation on 60 Hz systems on request. With pure coupling operation with flexible
coupling, the calculated bearing life is L10h greater than 50000 hours. Comply with the grease
service life and relubrication intervals.
Reinforced roller bearings
Size
Grease stability time for permanent lubrication or relubrication interval
for a regreasing system in operating hours at rated speed
Grease filling quantity for
permanent
lubrication or grease
quantity for relubrication
in g per bearing
Horizontal type of construction (B)
Vertical type of construction (V)
Permanent
lubrication
Relubricatio
n
3000
rpm
1500
rpm
≤1000
rpm
3000
rpm
1500
rpm
≤1000
rpm
180
2800
5600
8000
2000
4000
5600
-
17
200
-
20
225
-
25
Maintenance
9.1 Inspection and maintenance
LOHER CHEMSTAR 1PS5
Operating Instructions 03/2014
89
Summary of Contents for SIMATIC S5 1P 243
Page 2: ...11 03 2014 02 49 V4 00 ...
Page 12: ...Introduction LOHER CHEMSTAR 1PS5 12 Operating Instructions 03 2014 ...
Page 20: ...Safety notes 2 11 Ventilation LOHER CHEMSTAR 1PS5 20 Operating Instructions 03 2014 ...
Page 66: ...Electrical connection 6 2 Connecting LOHER CHEMSTAR 1PS5 66 Operating Instructions 03 2014 ...
Page 124: ...Disposal 11 4 Disposal of components LOHER CHEMSTAR 1PS5 124 Operating Instructions 03 2014 ...
Page 136: ...Quality documents C 4 Data LOHER CHEMSTAR 1PS5 136 Operating Instructions 03 2014 ...
Page 140: ...Index LOHER CHEMSTAR 1PS5 140 Operating Instructions 03 2014 ...
Page 141: ...AC EC Declaration of Conformity U161 AB EC Declaration of Conformity U163 AA R No 20000h U165 ...