background image

 

SIMATIC RTLS4060T 

 

Manual, 06/2019, C79000-G8976-C550-02

 

 

 

 

9

 

 

 

4

 

Technical specifications 

4.1

 

Connections and supply voltage 

Connections and supply voltage 

Voltage 

10 ... 30 V DC, rated voltage 24 V DC 

Energy intake 

3.5 W 

Plug-in cable 

8-pin plug-in connector – cable socket PX0410/08S/6065 

4.2

 

Digital inputs and outputs 

 
 
 
 
 
 
 

Digital inputs 

Input voltage 

0 to 24 V DC 

Input impedance 

4.7 kOhm 

Digital outputs 

Output 

High-side switch -> Connect to input voltage 

Output current 

Max. 250 mA, short-circuit proof 

Output voltage 

0 V or supply voltage 

Load 

Any; inductive loads up to 32 H do not require a freewheeling 
diode. If a freewheeling diode is used, a polarity protection 
diode must also be used. 

Summary of Contents for SIMATIC RTLS4060T

Page 1: ...06 2019 C79000 G8976 C550 02 SIMATIC RTLS Localization systems SIMATIC RTLS4060T Manual ...

Page 2: ...or the intended purpose taking into account the documentation relating to the intended purpose and in particular the safety and warning notices it contains Due to training and experience qualified personnel is capable of recognizing risks and avoiding possible dangers when handling these products systems Proper use of Siemens products Note the following WARNING Siemens products may only be used fo...

Page 3: ... for power digital output 6 2 2 2 Digital output 7 2 2 3 Digital input 7 3 Installation commissioning safety 8 3 1 General information 8 3 2 Installation and operation 8 3 3 Connection of the cable 8 3 4 Recycling and disposal 8 4 Technical specifications 9 4 1 Connections and supply voltage 9 4 2 Digital inputs and outputs 9 4 3 Wireless 10 4 4 Environment 10 5 Approvals 11 5 1 EU declaration of ...

Page 4: ...work anchors and gateways which send the data to the localization server for calculation and visualization The device is suitable for installation in vehicles and other devices and is connected to the supply voltage there 1 2 Delivery contents and accessories 1 SIMATIC RTLS4060T article number 6GT2700 6DE03 Accessories not included in scope of delivery 1 connecting cable article number 6GT2791 1AH...

Page 5: ...SIMATIC RTLS4060T Manual 06 2019 C79000 G8976 C550 02 5 2 Dimension drawing and connections 2 1 Dimension drawing ...

Page 6: ... connector for power digital output 8 pin plug in connector 3 m cable with socket article number 6GT2791 1AH30 Pin Description Conductor color 1 24 V DC Red 2 GND 0 V Black 3 Digital output Brown 4 Digital input 2 Orange 5 Digital input 1 Yellow 6 CAN L Green 7 CAN H Blue 8 Not used Violet ...

Page 7: ...s The following must be observed for inductive loads e g relays Inductivities up to 32 H can be switched off without the DV freewheeling diode A freewheeling diode DV is required for higher inductivities If a freewheeling diode DV is used an additional polarity protection diode DP must be inserted 2 2 3 Digital input The device has 2 digital inputs Each has a range from 0 to 24 V with an impedance...

Page 8: ...e environmental conditions must be observed during installation and operation of the devices The ambient temperature of the device must not exceed 50 C Avoid installation locations exposed to direct sunlight The devices must be installed in accordance with the respective instructions for the installation of electrical systems and utilities 3 3 Connection of the cable Make sure the wiring is correc...

Page 9: ...in connector cable socket PX0410 08S 6065 4 2 Digital inputs and outputs Digital inputs Input voltage 0 to 24 V DC Input impedance 4 7 kOhm Digital outputs Output High side switch Connect to input voltage Output current Max 250 mA short circuit proof Output voltage 0 V or supply voltage Load Any inductive loads up to 32 H do not require a freewheeling diode If a freewheeling diode is used a polari...

Page 10: ...E communications and optional localization Wireless process IEEE 802 15 4 Frequency range 2 40 2 48 GHz ISM band Transmit power Max 100 mW can be set Min 0 00025 mW can be set Bandwidth 2 MHz data transmission on 802 15 4 channels adjustable Antenna Built in 2 4 GHz antenna 4 4 Environment Environment Housing PC plastic enclosure Degree of protection IP65 Dimensions 151 x 66 x 43 mm Weight 180 g T...

Page 11: ...fficial journal of the EU L174 1 July 2011 pages 88 110 Radio Equipment Directive 2014 53 EU RED Directive of the European Parliament and of the Council of 16 April 2014 on the harmonization of the laws of the member states relating to placing radio equipment on the market official journal of the EU L153 22 May 2014 pages 62 106 5 2 RoHS RoHS directive restriction of the use of certain hazardous s...

Page 12: ...dio equipment and services Part 1 Common technical requirements ETSI EN 301 489 17 Electromagnetic compatibility and radio spectrum matters ERM Electromagnetic compatibility for radio equipment and services Part 17 Specific conditions for broadband data transmission systems EN 55011 Industrial scientific and medical ISM radio frequency equipment Electromagnetic disturbance characteristics Limits a...

Page 13: ... Efficient use of the radio spectrum ETSI EN 300 328 Wideband transmission systems Data transmission equipment operating in the 2 4 GHz ISM band and using wide band modulation techniques Harmonized standard covering the essential requirements of article 3 2 of the EU Directive 2014 53 EU Note The specified approvals are only valid if the corresponding symbol is printed on the device ...

Reviews: