background image

 

 

SIMATIC RTLS4030G 

 

SIMATIC RTLS 

Localization systems 

SIMATIC RTLS4030G 

Operating Instructions 

 

 

06/2020 

C79000-G8976-C515-03 

Introduction 

 

 

Device description 

 

 

Installation & Operation 

 

 

Technical specifications 

 

 

Approvals 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for SIMATIC RTLS Series

Page 1: ...LS4030G SIMATIC RTLS Localization systems SIMATIC RTLS4030G Operating Instructions 06 2020 C79000 G8976 C515 03 Introduction 1 Device description 2 Installation Operation 3 Technical specifications 4 Approvals 5 ...

Page 2: ...ly by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens prod...

Page 3: ...er data RTLS4030G 10 2 3 Pin assignment 11 2 4 LED status indicator 12 2 5 Dimension drawing 13 2 6 Troubleshooting 13 3 Installation Operation 15 3 1 Notes on installation 15 3 2 Mounting for ceiling mount 18 3 3 Mounting for corner and pole mount 19 3 4 Ethernet 19 3 5 Operation 20 3 6 Cleaning and maintenance 20 4 Technical specifications 21 5 Approvals 23 ...

Page 4: ...Table of contents SIMATIC RTLS4030G 4 Operating Instructions 06 2020 C79000 G8976 C515 03 ...

Page 5: ...following device RTLS4030G CE article number 6GT2701 5DB03 RTLS4030G FCC NOM article number 6GT2701 5DB13 RTLS4030G CMIIT article number 6GT2701 5DB23 Further documentation The system manual Commissioning SIMATIC RTLS provides information on other SIMATIC RTLS products that you can operate together with the devices in this product line in an Industrial Ethernet network You can find the system manu...

Page 6: ... contact our customer consultants at the following Internet address https new siemens com global en products services industry sitrain personal html Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants systems machines and networks In order to protect plants systems machines and networks against cyber threats it...

Page 7: ...posal The products are low in harmful substances can be recycled and meet the requirements of the Directive 2012 19 EU for disposal of waste electrical and electronic equipment WEEE Do not dispose of the products at public disposal sites For environmentally compliant recycling and disposal of your electronic waste please contact a company certified for the disposal of electronic waste or your Siem...

Page 8: ...Introduction SIMATIC RTLS4030G 8 Operating Instructions 06 2020 C79000 G8976 C515 03 ...

Page 9: ...n Ethernet port Alternative power supply using Power over Ethernet PoE General The device is the home location for localiza tion in the RTLS localization system It can be connected to the local IT infrastruc ture over Ethernet This connection sets up an exchange between the node the RTLS localization network and the Locat ing Manager server Area of application The device is suitable for operation ...

Page 10: ...tor made of plastic for cable mounting IP65 to gateway 6GT2790 0CB00 Holder for gateways for ceiling mounting 6GT2790 0BE20 Holder for gateways for corner and mast mounting 6GT2790 0BE30 Connecting cable for connection to wide range power supply unit for gateways 5 m 6GT2791 2PH50 Wide range power supply with power cable EU 6GT2898 0AC00 UK 6GT2898 0AC10 US 6GT2898 0AC20 Wide range power supply wi...

Page 11: ...lug in connectors shown below When connecting the Ethernet cable ensure that the twist lock connectors are correctly secured Connections 3 pin plug in connector Buccaneer PX0412 03P Connectors SA3350 1 Sealing cover PX0480 The pins are occupied as illustrated below Pin Description 1 Mains supply red 8 30 V DC 2 Digital output brown Switched input voltage max current 200 mA 3 Grounding terminal bla...

Page 12: ...ied to the device through the mains cable RADIO LED Off when the radio signal of the device to other gateways or transponders is inactive RADIO LED Flashes yellow when the radio signal of the device to other gateways or transponders is active LAN SERVER LED Lights up blue when the device has an Ethernet connection and a connection to the Locat ing Manager LAN SERVER LED Flashes blue once per secon...

Page 13: ...ooting Error detection Cause of the error Troubleshooting Device does not respond all LEDs are off The device is not connected or the power supply unit is not switched on Check the supply voltage of the device The blue LED LAN SERVER is off Device has no Ethernet connection Check the local network and the firewall The blue LED LAN SERVER flashes once per second Device is not connected to the Locat...

Page 14: ...Device description 2 6 Troubleshooting SIMATIC RTLS4030G 14 Operating Instructions 06 2020 C79000 G8976 C515 03 ...

Page 15: ... cover Note the specifications in the section Technical specifications Page 21 during installation and operation Ensure that all screws are securely and firmly screwed into the wall ceiling and can support the weight of the device and its wiring Make sure that the ambient temperature does not exceed 50 C and that the device is not installed in a location where it is exposed to direct sunlight Conn...

Page 16: ...taneous supply voltage Do not supply the device with power through the mains and the PoE connection at the same time Check whether the rated voltage of the power supply corresponds to the values in the section Technical specifications Page 21 CAUTION Safety extra low voltage The equipment is designed for operation with Safety Extra Low Voltage SELV by a Limited Power Source LPS This does not apply...

Page 17: ...e without holder to the wall 1 Draw the bore holes on the wall according to the following drilling pattern 2 Drill the holes with a suitable device 3 Insert the suitable anchors in the holes Anchors are not supplied with the device 4 Mount the device to the wall using screws M4 Screws are not supplied with the device Figure 3 1 Drilling pattern All dimensions specified in millimeters ...

Page 18: ...ling 1 Use the mounting plate as template and draw the bore holes on the ceiling 2 Drill the holes with a suitable device 3 Insert the suitable anchors in the holes Anchors are not supplied with the device 4 Mount the mounting plate to the ceiling 5 Install the device to the mounting plate using the screws M4 Screws are not supplied with the device Figure 3 2 Ceiling support all dimensions specifi...

Page 19: ...g the screws M4 Screws are not supplied with the device Figure 3 3 Universal support all dimensions specified in millimeters Note If drilling is not possible you can also fasten the universal support to the given position using with cable ties for example 3 4 Ethernet When installing and connecting the Ethernet connection observe the applicable general conditions and their legal basis The Ethernet...

Page 20: ...n objects are entering the device the device must be disconnected from the power supply and maintenance must be contacted immediately 3 6 Cleaning and maintenance The device may only be opened by suitably trained and qualified users Only authorized dealers are permitted to repair the device Unauthorized opening of and improper repairs to the device may cause substantial risks to the user As soon a...

Page 21: ...MHz 4800 MHz CE FCC NOM 6000 MHz 7000 MHz CE FCC NOM CMIIT Transmit power 0 037 mW 41 3 dBm MHz Range Maximum 30 m Accuracy of the localization typical 0 2 m Antennas Built in UWB antenna PHASE radio frequencies Wireless method IEEE 802 15 4 Transmission speed 1 Mbit s Operating frequency rated value 2400 2480 MHz ISM band Bandwidth 2 MHz data transmission on 802 15 4 channels configura ble Freque...

Page 22: ...ions Ambient temperature During operation During storage During transport 15 50 C 15 50 C 15 50 C Design dimensions weights and connectors Dimensions L x W x H 180 x 180 x 48 mm Weight 650 g Degree of protection IP65 Method of securing Fixed mounting on walls or ceilings Enclosure Plastic enclosure ASA and PC UV resistant Color Titanium gray Power plug 3 pin plug in connector with screw type termi...

Page 23: ...cial journal of the EU L153 22 May 2014 pages 62 106 RoHS directive restriction of the use of certain hazardous substances The products described in these operating instructions meet the requirements of the EU directive 2011 65 EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment Applied standard EN 50581 Technical documentation for the assessment...

Page 24: ...quipment and services Part 33 Special conditions for ultra wideband UWB devices EN 55011 Industrial scientific and medical equipment Radio frequency disturbance characteristics Limits and methods of measurement EN 55032 Class A Class B Electromagnetic compatibility of multimedia equipment Emission requirements EN 55035 Electromagnetic compatibility of multimedia equipment Immunity requirements EN ...

Page 25: ...s Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Note This equipment has b...

Page 26: ...950 1 EN60950 1 VDE0805 1 must be connected to the power supply terminals The power supply unit for the equipment power supply must comply with NEC Class 2 as described by the National Electrical Code r ANSI NFPA 70 WARNING Alimentation Cet appareil est conçu pour fonctionner à une très basse tension de sécurité Safety Extra Low Voltage SELV fournie par une alimentation électrique à puissance limi...

Reviews: