![Siemens Simatic RF382R Scanmode Compact Operating Instructions Download Page 6](http://html.mh-extra.com/html/siemens/simatic-rf382r-scanmode/simatic-rf382r-scanmode_compact-operating-instructions_374418006.webp)
SIMATIC RF382R Scanmode
6
J31069-D0214-U001-A4-7618, 10/2013
7
Traversing speed with RF382R Scanmode
The following table shows the traversing speed of a transponder through the main field. The direction of motion of the
transponder is horizontal.
Table 7-1
Traversing speed of different transponders
MDS D124
MDS D160
MDS D460
MDS D324
MDS D424
UID number
(8 bytes)
1.5 m/s
1.5 m/s
1.5 m/s
8
Field data of transponders and readers
The following tables show the field data of transponders with SIMATIC RF382R Scanmode. The technical specifications
listed below are typical data and apply at an ambient temperature of +22 °C.
Tolerances of ±20% are admissible due to production and temperature conditions.
Field data horizontal field
Table 8-1
Length of the transmission window L
MDS D124
MDS D160
MDS D324
MDS D424
MDS D460
60
50
60
65
50
All dimensions in mm
Table 8-2
Usable field width with dynamic operation (median deviation) in mm
MDS D124
MDS D160
MDS D324
MDS D424
MDS D460
20
20
20
20
20
All dimensions in mm
Table 8-3
Operating range
MDS D124
MDS D160
MDS D324
MDS D424
MDS D460
40…65
35….50
40…65
40…65
30…50
All dimensions in mm
Table 8-4
Limit distance
MDS D124
MDS D160
MDS D324
MDS D424
MDS D460
75
65
75
75
60
All dimensions in mm