Configuring with the WBM
7.3 The menu items of the WBM
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
Operating Instructions, 04/2020, C79000-G8976-C512-03
73
Parameter
Parameter value
Default value
Description
Read point name
--
--
In the text box, you can assign a name to the
read point(s) (for example, "Incoming goods
gate 5" or "Welding robot 21"). Note that the
name is required for addressing the reader via
OPC UA.
Transmission
speed
19.2 kBd
57.6 kBd
115.2 kBd
921.6 kBd
115.2 kBd /
921.6 kBd
Selection depends on the Ident device/system
being used. With this parameter, you set the
data transmission speed between the commu-
nication module and the reader.
User mode
Ident profile/RFID stand-
ard profile
FB 45
Ident profile/RFID
standard profile
Shows which block has been set in STEP 7:
•
Ident profile/RFID standard profile:
The program block for the Ident profile/RFID
standard profile is used on the controller.
•
FB 45:
Single tag mode. FB 45
(PROFIBUS/PROFINET) is used in the con-
troller.
The parameter values of the basic parameters can be preset automatically using the
"Autoconfiguration" button. By pressing the button, the communication module automatically
identifies the device connected to the interface and sets the appropriate parameter values.
Using the "Update firmware" link, you jump to the "System - Reader firmware" menu item in
which you can update firmware for the connected reader.
Reader parameters
If you have selected the "General reader" parameter value in the "Ident devices/system"
parameter, the reset parameters of the reader connected to the interface are displayed in
hexadecimal format in this area. You can find more detailed information on this in the "Ident
profile and Ident blocks, standard function for Ident systems
https://support.industry.siemens.com/cs/ww/en/view/109762333
)" manual.