Programming via OPC UA
9.2 OPC UA variables
SIMATIC RF166C
106
Operating Instructions, 12/2019, C79000-G8976-C578-01
9.2.3
SimaticIdentModelVersion
Table 9- 5
SimaticIdentModelVersion
Path
Root/Objects/DeviceSet/Read_point_x/RuntimeParameters/Sima
ticIdentModelVersion
Data type
String
Access
R
Description
Indicates the version of the OPC UA module.
Possible values
Example:
V1.1.0
9.2.4
CommonSettings
You can make basic settings on the communication module using these variables.
Table 9- 6
CodeTypes
Path
Root/Objects/DeviceSet/Read_point_x/RuntimeParameters/Com
monSettings/CodeTypes
Data type
UInt32
Access
R/W
Description
Definition of the data type for all AutoID identifiers in "AutoID
Standard".
The setting has an effect specifically on the data type of the
"LastScanData", variable, the "Identifier" diagnostics variable and
the "ScanData" union used for the "Identifier" in methods or
events.
The types "String", "ByteString" and "ScanDataEpc" are support-
ed. The type definition of "CodeTypes" is "MultiStateDiscrete-
Type". This means that the variable has an "Enum" that indicates
the supported data types as "Property".
Possible values
•
0: ByteString
•
1: String
•
2: ScanDataEpc
Summary of Contents for SIMATIC RF166C
Page 6: ...Table of contents SIMATIC RF166C 6 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Page 20: ...Description 3 3 Design SIMATIC RF166C 20 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Page 160: ...Dimensional drawings SIMATIC RF166C 160 Operating Instructions 12 2019 C79000 G8976 C578 01 ...
Page 176: ...Service Support SIMATIC RF166C 176 Operating Instructions 12 2019 C79000 G8976 C578 01 ...