To close the unit, proceed as follows:
1. Tilt the unit to the horizontal position.
2. Place the front section on the casing at an angle (the guide studs at the top
edge must fit into place).
3. Insert the CD-ROM ribbon cable into the drive connector on the
backplane.
4. Press the front section onto the lower edge of the casing until the catches in
the base engage.
5. Insert the battery into the battery compartment and connect it up.
6. Close the battery cover.
7. Connect the keyboard connector to the back of the unit. Make sure that
the cable is inserted in its channel.
8. Insert the keyboard cable in the cable conduit at the base of the device.
9. Allow the keyboard hinge to slide into the receptacles in the base of the
device.
10. Tilt the unit back into the operating position.
Your PG 720 is now ready for operation again.