1-34
SIMATIC PC BI45/FI45 PII, Technical Description
C79000-G7076-C794-03
You can connect the BIxx/FIxx to a SIMATIC S5 programmable controller
via the COM1/TTY interface port.
Connect your BIxx/FIxx to a SIMATIC S5 programmable controller as
follows:
1. Switch off the BIxx/FIxx.
2. Plug the cable into the COM1/V.24 PLC interface port.
!
Caution
Risk of damage to the BIxx/FIxx!
The interface port may be damaged if you confuse the connections or use the
wrong connecting cables. Make sure the TTY cable of the BIxx/FIxx is
plugged into the COM1/TTY port and not into the LPT1 port.
Before plugging in the cables, you must discharge your body’s electrostatic
charge by briefly touching a grounded object (ESD guideline).
Use only the original cables to establish the connection to the programmable
controller.
The BIxx/FIxx and the programmable controller must be operated at the same
protective ground potential.
An adapter is available for connecting the programmable controller using
older standard cables.
Interface
Link
Connecting Cable
Adapter
BI
/FI
6ES5 734-2BD20
TTY interface
(COM1)
BIxx/FIxx to
SIMATIC S5
programmable
6ES5 731-1xxx0
15-pin
6ES5 731-6AG00
(COM1)
programmable
controller
6ES5 731-0xxx0
25-pin
6ES5 731-6AG00
In order to maintain a data transfer rate of 9600 bps up to a distance of over
1000 m (3300 ft), the receiving diode is connected to ground (reference) via
the connecting cable. Cables of various lengths are available under the Order
No. 6ES5 734-2xxx0 (xxx stands for the length in meters).
Connecting the
BIxx/FIxx to S5
Programmable
Controllers
Connecting the
BIxx/FIxx via an
Adapter
Higher Data
Transfer Rates at
Distances of up to
1000 m (3300 ft.)
System Unit