Functions specific to SCALANCE
4.5 Spectrum analyzer
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
111
4.5.2.2
wlan spectrumanalyzer start (Access Point)
Description
With this command you start measurement with the spectrum analyzer. If you start a new
measurement, the previous measurement will be overwritten.
Note
This command is available only in access point mode.
Note
When the spectrum analyzer is started, all WLAN connections are terminated on both WLAN
interfaces. The access point then also does not send any beacons.
Note
Do not enable the spectrum analyzer if the device is operating productively. This can
influence the performance of the device.
Note
The functionality of the spectrum analyzer does not replace a dedicated spectrum analyzer.
Requirement
●
The WLAN interface is enabled.
●
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call the command without parameter assignment:
wlan spectrumanalyzer start
Result
The measurement is started. The measured values are logged in a file.
Further notes
You stop the recording with the
wlan spectrumanalyzer stop
command.
You display the settings of the spectrum analyzer with the
show wlan spectrumanalyzer
command.