Configuring with Web Based Management
5.3 "Wizard" menu
SCALANCE W760/W720 to IEEE 802.11n Web Based Management
46
Configuration Manual, 11/2014, C79000-G8976-C350-03
5.3.1.4
Management Interfaces
System configuration
On this Basic Wizard page, you specify the services with which the device can be accessed.
With some services, there are further configuration pages on which more detailed settings
can be made. Configure these services after completing the Basic Wizard.
Description
The page contains the following boxes:
●
"Telnet Server" check box
Enable or disable the "Telnet Server" service for unencrypted access to the CLI.
●
"SSH Server" check box
Enable or disable the "SSH Server" service for encrypted access to the CLI.
●
"HTTPS Server only" check box
Enable or disable access using HTTPS.
●
"DCP Server" drop-down list
Specify whether or not the device can be accessed with DCP (Discovery and
Configuration Protocol):
–
"-" (disabled)
DCP is disabled. Device parameters can neither be read nor modified.
–
Read/Write
With DCP, device parameters can be both read and modified.
–
Read-Only
With DCP, device parameters can be read but cannot be modified.