Connection
6
6.1
Safety when connecting up
Safety notices
When connecting up the device, keep to the safety notices listed below.
Note
Strain relief for the Ethernet cables
In order to avoid mechanical stress on the Ethernet cables and resulting interruption of
the contact, fasten the cables at a short distance from the connector using a cable guide
or busbar.
Lightning protection
WARNING
Danger due to lightning strikes
Antennas installed outdoors must be within the area covered by a lightning protection
system. Make sure that all conducting systems entering from outdoors can be
protected by a lightning protection potential equalization system.
When implementing your lightning protection concept, make sure you adhere to the
VDE 0182 or IEC 62305 standard.
Suitable lightning protectors are available in the accessories (Page 23) of SIMATIC NET
Industrial WLAN.
Note
We recommend that you use the maintenance-free lightning protector LP798-2N.
Exception: When there is also DC power supplied via the antenna cable. In this case,
only the lightning protector LP798-1N can be used.
Summary of Contents for SIMATIC NET SCALANCE W720
Page 8: ...Introduction SCALANCE W760 W720 8 Operating Instructions 03 2022 C79000 G8976 C322 13 ...
Page 10: ...Safety notices SCALANCE W760 W720 10 Operating Instructions 03 2022 C79000 G8976 C322 13 ...
Page 56: ...Dimension drawings SCALANCE W760 W720 56 Operating Instructions 03 2022 C79000 G8976 C322 13 ...
Page 58: ...Approvals SCALANCE W760 W720 58 Operating Instructions 03 2022 C79000 G8976 C322 13 ...