Configuration limits of the device
The following table lists the configuration limits for Web Based Management and the
Command Line Interface of the device.
Configurable function
Maximum number
System
DNS Server
2
DNS Entries
128
Domain name: Maximum of 256
characters
Syslog server
3
SNMPv1 trap receiver
10
SNTP server
1
NTP server
4
NTP (secure) server
4
DHCP pools
8
IPv4 addresses managed by the DHCP
server (d static)
100
Static assignments per DHCP pool
128
DHCP options (3, 6, 12, 15, 66, 67)
5
SINEMA RC
1
Proxy server
5
Layer 2
Virtual LANs (port-based; including VLAN 1)
257
Layer 3
IP interfaces
32
Static routes
100
Possible routes to the same destination
8
NAPT
1000
Source NAT
1000
NETMAP rules
1000
NETMAP rules in conjunction with VRRPv3
1000
Alias IP addresses
1024
VRRPv3
VRRPv3 instances (VRID): 16
Assigned IP addresses: 1 per VRID
Security
Users
30
Groups
32
Roles
32
RADIUS Server
4
NAT rules
1000