Technical Specifications
5.3 Operating Environment
5.3
Operating Environment
The RUGGEDCOM RX1511 is rated to operate under the following environmental
conditions.
IMPORTANT
Temperature limits for select line modules may differ from that which can be
withstood by the RUGGEDCOM RX1511. Make sure the selected modules are
rated for the expected environmental conditions before deployment. For more
information, refer to the
RUGGEDCOM RX1511 Series Modules Catalog
.
Ambient Operating
Temperature
-40 to 85 °C (-40 to 185 °F)
Ambient Storage Temperature
-40 to 85 °C (-40 to 185 °F)
Ambient Relative Humidity
5% to 95%
Maximum Altitude
2000 m (6562 ft)
Maximum ambient operating temperature is 70 °C (158 °F) when the device is installed along with
Underwriter Laboratories (UL) listed devices.
Measured from a 30 cm (12 in) radius surrounding the center of the enclosure.
Operating temperature may vary based on the limitations of installed SFPs. Refer to the
RUGGEDCOM
SFP Transceivers Catalog
for SFP temperature ratings.
Non-condensing.
5.4
Mechanical Specifications
Weight
Approximately 3.2 kg (7 lb)
Ingress Protection
IP30
Enclosure
Aluminum
5.5
Dimension Drawings
Note
All dimensions are in millimeters, unless otherwise stated.
46
RUGGEDCOM RX1511
Installation Manual, 01/2021, C79000-G8976-1056-19