Device Management
3.2 Configuring the Device
The management port is a 10/100Base-TX copper Ethernet port with an RJ45 connec-
tor. The following is the pin-out for the management port:
8
1
Figure 3.2
RJ45 Management Port
Pin
Name
Description
1
TX+
Transmit Data+
2
TX-
Transmit Data-
3
RX+
Receive Data+
4
Reserved (Do Not Connect)
5
Reserved (Do Not Connect)
6
RX-
Receive Data-
7
Reserved (Do Not Connect)
8
Reserved (Do Not Connect)
Communication Ports
Connect any of the available Ethernet ports on the device to a management switch
and access the RUGGEDCOM RSG2488F console and Web interfaces via the device's
IP address. The factory default IP address for the RUGGEDCOM RSG2488F is
For more information about available ports, refer to
3.2
Configuring the Device
Once the device is installed and connected to the network, it must be configured. All
configuration management is done via the RUGGEDCOM RSG2488F interface. For
more information about configuring the device, refer to the
RUGGEDCOM RSG2488F
User Guide
associated with the installed software release.
3.3
Inserting/Removing the MicroSD Card
The RUGGEDCOM RSG2488F accepts a microSD card for storing configuration files
and/or software updates.
CAUTION
Configuration hazard – risk of data loss
The microSD card must not be removed or replaced during normal operation of the
device. Make sure the device is powered down before removing or inserting the
card.
CAUTION
Mechanical/electrical hazard – risk of damage to the microSD card
• Do not expose the microSD card to extreme temperatures or humidity
20
RUGGEDCOM RSG2488F
Installation Manual, 11/2019, C79000-G8976-1351-05