Device Management
3
This section describes how to connect to and manage the device.
3.1
Connecting to the Device
The following describes the various methods for accessing the RUGGEDCOM
RS900GPF console and Web interfaces on the device. For more detailed instructions,
refer to the
RUGGEDCOM RS900GPF User Guide
for the RUGGEDCOM RS900GPF.
Serial Console Port
Connect a PC or terminal directly to the serial console port to access the boot-time
control and RUGGEDCOM ROS console interface.
IMPORTANT
The serial console port is intended to be used only as a temporary connection during
initial configuration or troubleshooting.
The serial console port implements RS-232 DCE (Data Communication Equipment) on
a DB9 connector. Use the following settings to connect to the port:
Speed
57600 baud
Data Bits
8
Stop Bit
1
Parity
None
Flow Control
Off
Terminal ID
VT100
The following is the pin-out for the port:
5
1
6
9
Figure 3.1
Serial DB9 Console Port
Pin
Name
Description
1
Reserved (Do Not Connect)
2
TX
Transmit Data
3
RX
Receive Data
4
Reserved (Do Not Connect)
5
GND
Signal Ground
6
Reserved (Do Not Connect)
7
Reserved (Do Not Connect)
8
Reserved (Do Not Connect)
RUGGEDCOM RS900GPF
Installation Manual, 01/2021, C79000-G8976-1353-05