Configuration
3.4 Other options when configuring a CP 243-1
CP 243-1
84
Operating Instructions, 03/2012, C79000-G8976-C244-02
Note
•
Comments are inserted in the file with the # character.
•
Valid e-mails must have entries in the fields TO, SU and TX.
•
The last character of a line is \n.
•
The recipient address TO and CC must not contain more than 64 ASCII characters.
•
The subject SU must not contain more than 128 ASCII characters
•
The e-mail text TX must not contain more than 1024 ASCII characters (incl. e-mail tags
and formatting characters)
•
The sender address FROM must not contain more than 64 ASCII characters.
•
All characters between 0x21 HEX and 0x7E HEX can be used for TO, CC, SU and TX if
this is accepted by the e-mail partners involved.
•
Empty lines are not permitted.
3.4.9
Structure of the configuration file for the FTP client (.fdb file)
The configuration file for the FTP client is created by the Internet wizard in STEP 7
Micro/WIN 32 and stored in a file with the extension .fdb. The structure of this file is shown in
the table below.
Table 3- 5
Structure of the configuration file for the FTP client
Keyword for the .fdb file
Description
Example
General section
TIMESTAMP
Time stamp
Time in seconds since 01.01.1970, in
hexadecimal format (PC time of the
creation of the *.fdb file by STEP 7
Micro/WIN 32).
During operation, the CP 243-1
continuously monitors this element for
changes. When a change is detected,
the .fdb file is read completely and the
FTP client service of the CP 243-1 is
reconfigured.
TIMESTAMP=3D2C4E48
Corresponds to 15:10:00 on July 10,
2002
FILETYPE
File type
Used internally by the system.
FILETYPE=FDB
Do not change, fixed value!
FILEFORMAT
File format
Used internally by the system
FILEFORMAT=xx
Do not change, fixed value!
Summary of Contents for SIMATIC NET CP 243-1
Page 6: ...Preface CP 243 1 6 Operating Instructions 03 2012 C79000 G8976 C244 02 ...
Page 10: ...Table of contents CP 243 1 10 Operating Instructions 03 2012 C79000 G8976 C244 02 ...
Page 104: ...Programming 4 5 ETHx_FTPC CP 243 1 104 Operating Instructions 03 2012 C79000 G8976 C244 02 ...
Page 124: ...Certification CP 243 1 124 Operating Instructions 03 2012 C79000 G8976 C244 02 ...
Page 138: ...Sample program CP 243 1 138 Operating Instructions 03 2012 C79000 G8976 C244 02 ...
Page 142: ...Index CP 243 1 142 Operating Instructions 03 2012 C79000 G8976 C244 02 ...