Service and maintenance
10.4 Module replacement
SIMATIC MV500
242
Operating Instructions, 03/2021, C79000-G8976-C494-05
10.4
Module replacement
Before replacing a module
WARNING
Read the manual of the SIMATIC controller you using
Prior to installation, connecting up and commissioning, read the relevant sections in the
manual of the SIMATIC controller you are using. When installing and connecting up, keep to
the procedures described in the manual.
CAUTION
Installation/removal with the power off
Wire up the SIMATIC controller and the modules and readers to be connected only when the
power is off. Make sure that the power supply is switched off when installing/uninstalling
the devices as well as the built-in ring light, EF lens and micro SD adapter.
NOTICE
Backing up the configuration
Prior to replacing the module, make sure that you back up the configuration stored on the
optical reader so that you can transfer this to the newly connected reader following module
replacement. The backup (* .xml) is made using the WBM via the "Device > System > Device
configuration" menu.
You can save the configuration on the PC or on an SD card.
Note
Compatibility and device replacement of SIMATIC MV440 and SIMATIC MV540
Note that the SIMATIC MV440 and SIMATIC MV540 devices are mutually compatible and can
be exchanged in a PROFINET IO network without any problems.
Note
The topology of the plant must be correctly configured
To replace the device without a removable medium, the topology of the system must be
correctly configured. Use the topology editor for this.
Summary of Contents for SIMATIC MV500
Page 10: ...Preface SIMATIC MV500 10 Operating Instructions 03 2021 C79000 G8976 C494 05 ...
Page 16: ......
Page 28: ......
Page 32: ......
Page 92: ......
Page 114: ......
Page 148: ......
Page 244: ......
Page 254: ......
Page 260: ......
Page 292: ......
Page 294: ...Service Support SIMATIC MV500 294 Operating Instructions 03 2021 C79000 G8976 C494 05 ...