Process interfacing via an automation system (PLC, PC)
9.8 Remote client
SIMATIC MV500
208
Operating Instructions, 03/2021, C79000-G8976-C494-05
If a slave device sends the result string "\02Slave01:\03DMC123\04" and read the"DMC123"
code first, the master device sends the "Slave01:DMC123" string to its TCP partner.
9.8
Remote client
The remote client interface is an HTTP-based interface. The remote client can trigger
functions using HTTP requests sent to the optical reader. To make this possible, you need to
configure an IP address in the WBM that corresponds to the address of the client. The optical
reader only processes the HTTP requests that have the configured IP address as the sender.
9.8.1
XML backup and XML restore
Note
Do not control at the same time via the control interface
Ensure throughout the entire automation process that nothing is controlled via the control
interface while the XML Backup and XML Restore functions are running. If control is
performed via the control interface, by setting the DISA bit for example, the "XML Backup"
and "XML Restore" functions cannot be executed.
Note
Backing up the diagnostic images before execution of the "XML Backup" and
"XML Restore" functions
Executing the "XML Backup" and "XML Restore" functions may delete any diagnostics images
in the optical reader memory.
If required, save the diagnostic images before you execute one of these functions.
Note
Keep "XML Backup" file safe
The "XML Backup" file contains sensitive data (password hash). For security reasons, keep the
"XML Backup" file in a safe place.
In order to be able to use these functions, an IP address for the remote client must be stored
in the WBM (Settings > Communication > Interfaces > Archiving/MMI).
Summary of Contents for SIMATIC MV500
Page 10: ...Preface SIMATIC MV500 10 Operating Instructions 03 2021 C79000 G8976 C494 05 ...
Page 16: ......
Page 28: ......
Page 32: ......
Page 92: ......
Page 114: ......
Page 148: ......
Page 244: ......
Page 254: ......
Page 260: ......
Page 292: ......
Page 294: ...Service Support SIMATIC MV500 294 Operating Instructions 03 2021 C79000 G8976 C494 05 ...