Process interfacing via an automation system (PLC, PC)
9.7 Scanner portal application
SIMATIC MV500
Operating Instructions, 03/2021, C79000-G8976-C494-05
205
String
"MO<p1><p2><p3><p4><p5><p6>" (Machine command set digital out)
Table 9- 61 String structure
Characters
Description
p1
Number of the logical external signal.
•
Two printable ASCII characters with value "1" to "4"
The values correspond to "EXT_1", "EXT_2", "EXT_3" and "EXT_4".
p2
Level of the signal
•
ASCII characters with the value "0" to "2".
–
0: Set level statically to "low".
–
1: Set level statically to "high".
–
2: Set level for configured pulse time to "high".
p3
Link type
•
ASCII characters with the value "1" to "7"
–
1: Logical "OR"
–
2: Logical "AND"
–
3: Logical "Exclusive OR"
–
4: no link
–
5: Logical "OR not"
–
6: Logical "AND not"
–
7: Logical "Exclusive OR not"
p4
Logical signal for linking.
If p3 = "4", the parameter has no significance.
•
ASCII characters with the value "0" to "5"
–
0: Logical signal "IN_OP"
–
1: Logical signal "TRD"
–
2: Logical signal "RDY"
–
3: Logical signal "READ"
–
4: Logical signal "MATCH"
–
5: Logical signal "NOK"
p5
Reserved
The value must be "0" to retain upwards compatibility.
p6
9.7
Scanner portal application
This section explains how to use multiple optical readers to implement a scanner portal
application.
In a scanner portal application, there is a large field of view that is covered by several
individual readers. The fields of view of the readers overlap. To prevent the same code being
output more than once, the individual readers (slaves) send their read result to a master
reader. The master reader synchronizes the individual results and prevents the output of
Summary of Contents for SIMATIC MV500
Page 10: ...Preface SIMATIC MV500 10 Operating Instructions 03 2021 C79000 G8976 C494 05 ...
Page 16: ......
Page 28: ......
Page 32: ......
Page 92: ......
Page 114: ......
Page 148: ......
Page 244: ......
Page 254: ......
Page 260: ......
Page 292: ......
Page 294: ...Service Support SIMATIC MV500 294 Operating Instructions 03 2021 C79000 G8976 C494 05 ...